Beyond the Airway: Positioning—The Cornerstone of Safe Anesthesia in Neonatal Hydrocephalus Surgery
Article History
-
Received: ,
Accepted: ,
,
How to cite this article: Nagaria A, Mungutwar P. Beyond the Airway: Positioning—The Cornerstone of Safe Anesthesia in Neonatal Hydrocephalus Surgery. J Neonatal Crit Care Anesth. doi: 10.25259/JNCCA_2_2026
Dear Editor,
Neonatal hydrocephalus presents unique anesthetic challenges that extend far beyond airway management and maintenance of anesthesia. While considerable attention has conventionally focused on intracranial pressure, cerebral perfusion, and shunt-related complications, one of the most fundamental yet under-recognized aspects of perioperative care is patient positioning. Positioning influences every stage of anesthetic management, from induction and airway control to intraoperative physiological stability and surgical access, and deserves greater recognition as one of the major determinants of outcome of a neurosurgical procedure.[1-4]
Unlike older children, neonates with hydrocephalus frequently present with disproportionate macrocephaly, making conventional supine positioning difficult or even hazardous. The enlarged occiput prevents neutral head alignment, limits neck extension, and complicates mask ventilation and direct laryngoscopy.[2,5] Attempts to force conventional positioning may increase intracranial pressure, impair cerebral venous drainage, and produce cervical malalignment. Consequently, positioning should not be regarded as a simple preparatory step but as an integral component of airway management.
Simple yet thoughtful modifications, including shoulder elevation, allowing the enlarged head to rest beyond the edge of the operating table, or using customized gel or doughnut supports, can significantly improve airway alignment while maintaining physiological positioning.[2,6] These maneuvers facilitate laryngoscopy, reduce repeated intubation attempts, minimize hemodynamic responses to airway manipulation, and decrease the risk of airway trauma. In many cases, successful airway management depends more on optimal positioning than on advanced airway equipment.[7]
The importance of positioning extends well beyond tracheal intubation. During ventriculoperitoneal shunt insertion, repeated head rotation and surgical tunneling increase the risk of displacement of the endotracheal tube, vascular access, and monitoring lines. Failure to anticipate these changes may result in hypoventilation, accidental extubation, interruption of drug administration, or inaccurate physiological monitoring.[3,4] Therefore, systematic reassessment of the airway, intravenous lines, and monitoring after every positional change should become a routine component of neonatal neuro anesthesia.
Positioning also directly influences physiological homeostasis. Excessive neck flexion, extension, or rotation may obstruct cerebral venous drainage, elevate intracranial pressure, and compromise cerebral perfusion. Inadequate body support can impair ventilation, reduce venous return, and predispose to pressure-related injuries. Conversely, careful positioning optimizes airway patency, facilitates ventilation, preserves cerebral hemodynamics, improves surgical exposure, and enhances overall perioperative stability. These benefits underscore that positioning is not merely a technical requirement but an active therapeutic intervention.[2,7]
Although technological advances have improved various aspects of neonatal neuroanesthesia, the challenge of positioning neonates with hydrocephalus remains inadequately addressed. Positioning continues to rely primarily on individual clinician experience rather than standardized evidence-based practice. Given its profound influence on airway management, cerebral hemodynamics, ventilation, and surgical exposure, there is a pressing need to develop dedicated positioning devices and consensus guidelines specifically for neonates with severe hydrocephalus. Standardizing positioning strategies has the potential to reduce perioperative complications and improve the safety and consistency of neurosurgical care in this vulnerable population. As neonatal neuro anesthesia continues to evolve, meticulous attention to positioning should remain one of its most fundamental principles.[7]
Ethical approval:
Institutional Review Board approval is not required.
Declaration of patient consent:
Patient’s consent not required as there are no patients in this study.
Conflicts of interest:
There are no conflicts of interest.
Use of artificial intelligence (AI)-assisted technology for manuscript preparation:
The authors confirm that there was no use of artificial intelligence (AI)-assisted technology for assisting in the writing or editing of the manuscript, and no images were manipulated using AI.
Financial support and sponsorship: Nil.
References
- A Practice of Anesthesia for Infants and Children (7th ed). Amsterdam: Elsevier; 2024.
- [Google Scholar]
- Anaesthesia for neurosurgical procedures in paediatric patients. J Neuroanaesthesiol Crit Care. 2012;4:120-34.
- [Google Scholar]
- Ventriculoperitoneal shunt and meningomyelocele: Anesthetic considerations. Update in Anesth. 2021;37:39-44.
- [Google Scholar]
- Anesthesia for Ventriculoperitoneal Shunt Insertion In: Anesthesia Tutorial of the Week 121. London: World Federation of Societies of Anesthesiologists; 2008.
- [Google Scholar]
- Anesthetic considerations for congenital hydrocephalus. Paediatr Crit Care J. 2015;1:55-61.
- [Google Scholar]
- Clinical Anesthesia for the Newborn and the Neonate Germany: Springer Nature; 2023.
- [CrossRef] [Google Scholar]